Set-Up & Operation ManualLectroCount® LCR® Electronic Registers(with SR210 software)E2650/E2651 Series Enclosure (Class I, Division 1)Operation: E

Seite 2 - Table of Contents

10Lap Pad Calibration & Set-UpSTEP 2: SECURITYPress the M1 Key to access a top-level menu. Press LLLLL to scroll to the SECURITY menu. Press ENT

Seite 3 - Truck Delivery System

11STEP 3: GENERAL SETUP CONTINUEDPress LLLLL and the cursor will move to:TIME HH:MM:SSThis field is used to set the LCR internal clock. The time, lik

Seite 4 - LCR System Components

12PRESET^Available preset options include NET, BOTH, GROSS, and NONE. Selecting NONE will disable pre-setting. Presetting NET, GROSS, or BOTH is allow

Seite 5 - LCR Specifications

13Lap Pad Calibration & Set-upSTEP 3: GENERAL SETUP CONTINUEDHDR^This field is used to select the line number of the ticket header that will be ed

Seite 6 - Lap Pad Operation

14Lap Pad Calibration & Set-upSTEP 4: SYSTEM CALIBRATIONFrom the top-level menu, use LLLLL to scroll to SYSTEM CALIBRATION. Press ENTER and the cu

Seite 7

15Lap Pad Calibration & Set-upSTEP 4: SYSTEM CALIBRATION CONTINUEDDECIMAL^This field allows you to choose between whole units, tenths and hundred

Seite 8

16STEP 4: SYSTEM CALIBRATION CONTINUEDT UNIT^This field allows you to choose the temperature units - Degrees Fahrenheit or Degrees Celsius. PressENTER

Seite 9 - BEFORE GETTING STARTED

17Lap Pad Calibration & Set-upSTEP 5: PRODUCT & SHIFT INFORMATIONPress ENTER and the cursor will move to:#^ (Product Number)This field is used

Seite 10 - STEP 3: GENERAL SETUP

18Lap Pad Calibration & Set-upSTEP 5: PRODUCT & SHIFT INFORMATION CONTINUEDUNITS^From this field, a unit of measure is selected. Choose GALLO

Seite 11

19Lap Pad Calibration & Set-upSTEP 6: PRODUCT CALIBRATIONPress M1 to return to the top-level menu. Press i to scroll to PRODUCT CALIBRATION.There

Seite 12

2Table of ContentsDescription Page NumberLCR System Components ... 4LCR Specifications ...

Seite 13 - General Setup - Screen 5

20Lap Pad Calibration & Set-upSTEP 6: PRODUCT CALIBRATION CONTINUEDCOMPENSATION TYPE^ CONTINUEDScroll through the choices: Linear F, Linear C, API

Seite 14 - STEP 4: SYSTEM CALIBRATION

21Lap Pad Calibration & Set-upSTEP 6: PRODUCT CALIBRATION CONTINUEDPRESETThe Gross Preset amount is entered here. When this amount is reached the

Seite 15

22Lap Pad Calibration & Set-upSTEP 6: PRODUCT CALIBRATION CONTINUEDAUX MULTThis field is used to convert the quantity delivered, (e.g. GALLONS, LI

Seite 16

23Lap Pad Calibration & Set-upSTEP 6: PRODUCT CALIBRATION CONTINUEDPT^This field is used to calibrate the meter/register at up to 10 dif ferent fl

Seite 17

24Lap Pad Calibration & Set-upMulti-point calibration allows a flowmeter to be used over a wide range of flow rates without experiencing a loss in

Seite 18 - CLR SHIFT?

25Lap Pad Calibration & Set-upMULTI-POINT CALIBRATION CONTINUEDStep 5:Refill the prover at the same flow rate as S tep 4 to verify that the meter

Seite 19 - STEP 6: PRODUCT CALIBRATION

26Lap Pad Calibration & Set-upMULTI-POINT CALIBRATION CONTINUEDStep 5:Set the LINEAR^ field to APPLIED and enter it. This puts the linearizing al

Seite 20

27Lap Pad Basic OperationPRESET DELIVERY WITH A LAP PAD CONTINUEDPRODUCT TYPE^This field displays the product type previously selected in CALIBRATION.

Seite 21

28Lap Pad Basic OperationPRESET DELIVERY WITH A LAP PAD CONTINUEDPRESETThe PRESET amount can be entered here. A preset of GROSS or BOTH must have bee

Seite 22 - (Prover Qty - Meter Qty)

29Diagnostics/Factory CalibrationMost of the DIAGNOSTICS fields are for DISPLAY ONLY. They contain information that can be useful in troubleshooting.

Seite 23

3Truck Delivery SystemTruck Delivery System!!!!!WARNINGWARNINGWARNINGWARNINGWARNINGPower, input and output (I/O) wiring must be inaccordance with the

Seite 24 - MULTI-POINT CALIBRATION

30Diagnostics/Factory CalibrationDIAGNOSTICS CONTINUEDPULSR FAULTSThis field displays the number of quadrature pulser faults detected during the last

Seite 25

31Recalibration/Proving without a Lap PadThe addition of two control buttons on the LCR allows for single point recalibration or proving without the n

Seite 26 - Lap Pad Basic Operation

32Recalibration/Proving without a Lap PadSINGLE POINT RECALIBRATION/PROVING CONTINUEDPress SELECT to advance to:Calibration - Screen 1, Product Number

Seite 27

33Recalibration/Proving without a Lap PadNOTE: If the new value entered is out of range for theLCR, "Error" will appear in the display . If

Seite 28

34Basic Operation without a Lap PadOnce the LCR has been calibrated, a Lap Pad is not required for daily use of the register. There are two push butt

Seite 29 - DIAGNOSTICS

35Basic Operation without a Lap PadDELIVERY & SELECTIONS MENU CONTINUEDRUN Position (Flowrate/Temp.) ContinuedPress SELECT a second time (within 5

Seite 30 - DIAGNOSTICS CONTINUED

36Basic Operation without a Lap PadDELIVERY & SELECTIONS MENU CONTINUEDPRINT Position (Product #/Totalizer)Turning the Selector Switch to the PRIN

Seite 31

37Basic Operation without a Lap PadDELIVERY & SELECTIONS MENU CONTINUEDPRINT Position (Product #/Totalizer) ContinuedA shift ticket is printed whe

Seite 32

38LCR Menu Flow ChartsSelector Switch STOP Position of Selector Switch22345.6DELIVERY TOTALProd 1PRODUCT NUMBERProd 2PRODUCT NUMBERProd 3PRODUCT NUMBE

Seite 33 - CONTINUED

39L6789.0GROSS OR NET TOTALIZERH12345GROSS OR NET TOTALIZERProd 1PRODUCT NUMBERProd 4PRODUCT NUMBERSELECTSELECTSELECTINCREASEINCREASE(If System is“Loc

Seite 34 - RUN Position (Flowrate/Temp.)

4LCR System ComponentsPump & PrintLap Pad Hand Held Computer Laptop ComputerCommunication andProgramming Devices

Seite 35

40LCR Troubleshooting GuideThe LCR troubleshooting guide covers most common problem situations. Call your local Liquid Controls ServiceCenter or the

Seite 36 - 11:44:00

41NOTE: Check for proper operating voltages before changing the circuit board. If the circuit board needs to be changed,be sure to remove all power t

Seite 37

42LCR Troubleshooting GuidePower to LCR interrupted during delivery.1. Check accessory power cable for damage. Ensure that the power, common and grou

Seite 38 - SELECT: Step through digits

43LCR Troubleshooting GuidePulser failure. 2. If the LCR display counter increments, this may indicate a mechanical problem. Contact your local Liqu

Seite 39

44LCR Troubleshooting Guide1. Insert a delivery ticket into the Epson printer and start a delivery.Foreign debris in system. 2. Move the selector swi

Seite 40 - LCR Troubleshooting Guide

45Appendix A - Compensation Types & ParametersThe table below shows the supported methods of calculating the Volume Correction Factor (VCF). The

Seite 41

46Appendix B - Operation Using VT 100 Compatible TerminalIf the LCR is operated using a VT 100 compatible terminal (instead of the LC Lap Pad), refer

Seite 42

47Appendix C - Error MessagesThe LCR was designed to perform diagnostic analysis of problems as they occur. If an error should occur, one of thefollo

Seite 43

48Appendix C - Error MessagesIf an error occurs during a delivery, the message "*FAULT: PRINT DIAGNOSTICS TICKET*" will appear on the delive

Seite 44

49Appendix C - Error MessagesDIAGNOSTIC MESSAGE LIST CONTINUEDDELIVERY END REQSTThis message appears when a PRINT command has been sent to the LCR sy

Seite 45

5LCR SpecificationsThe LectroCount LCR is a microprocessor based electronic register that offers the same advanced operation as previ-ous LectroCount

Seite 46

50Appendix C - Error MessagesDIAGNOSTIC MESSAGE LIST CONTINUEDNET PRESET ACTIVEThis message appears when a NET PRESET is active. The PRESET type mu

Seite 47 - Appendix C - Error Messages

51Appendix D - Lap Pad Menu Flow ChartsGENERAL SETUPPress Enter or Scroll with ARROW keys.SYSTEM CALIBRATIONPress Enter or Scroll with ARROW keys.PROD

Seite 48

52Appendix D - Lap Pad Menu Flow ChartsDELIVERY & PRESETPress Enter or Scroll with ARROW keys.PRICE/UNIT TAX/UNIT % TAX 0.0000

Seite 49

53Appendix D - Lap Pad Menu Flow ChartsPRODUCT & SHIFT#^ SHIFT GROSS SHIFT NET UNITS^1 0.0 0.0 GALLONS#^ GROSS

Seite 50

54Appendix D - Lap Pad Menu Flow ChartsGENERAL SETUPPRINT GROSS & PARAM? VOL CORRECTED MSG?YES YESSALE # TICKET # UNIT ID

Seite 51 - GENERAL START UP

55Appendix D - Lap Pad Menu Flow ChartsSYSTEM CALIBRATIONCALIB # CALIB EVENT CONFIG EVENT 1 17 41UNITS^ RATE BASE^

Seite 52 - DELIVERY & PRESET MENU

56Appendix D - Lap Pad Menu Flow ChartsPRODUCT CALIBRATIONENTERM# M1M1M1M1M#PRODUCT CALIBRATIONPress Enter or Scroll with ARROW keys.#^ CODE PRODU

Seite 53 - PRODUCT & SHIFT

57SECURITYFACTORYDIAGNOSTICSAppendix D - Lap Pad Menu Flow ChartsDIAGNOSTICSPress Enter or Scroll with ARROW keys.SOFTWARE LANGUAGE TICKETSR2

Seite 54 - GENERAL SETUP

58This guide has been created to clearly convey the method for proving a meter system equipped with a LectroCountLCR electronic register without the u

Seite 55 - SYSTEM CALIBRATION

59k-Factor Adjustment Example:Presume that the LCR register displayed "101.235" Units and the prover volume was determined to be "100.5

Seite 56 - PRODUCT CALIBRATION

6Lap Pad OperationThis section of the manual provides instructions for theinitial set-up, calibration and operation of your LCR Elec-tronic Register u

Seite 57 - SECURITY

© 2007 Liquid ControlsPub. No. 500050(05/07)A Unit of IDEX Corporation105 Albrecht DriveLake Bluff, IL 60044-22421.800.458.5262 • 847.295.1050Fax: 8

Seite 58

7When the LCR is powered up with a Lap Pad att ached, the Lap Pad will briefly display a copyright message for twoseconds followed by the initial top-

Seite 59

8Each of the top-level menus has a secondary level consisting of one or more screens. Each screen is divided into oneor more fields where data may be

Seite 60

9Lap Pad Calibration & Set-Up• Make sure that the Lap Pad or other dat a entry device is connected to the LCR register as described in the LCRInst

Kommentare zu diesen Handbüchern

Keine Kommentare